2019 CORROTEC ZINC NICKEL PROCESS MANUAL PLATING LINE

Manufacturer

Not provided

Model

Not provided

Year

2019

Stock #

Not provided

Condition

Like New

Request A Quote

Keep Scrolling To Learn More

Image coming soon!

Specifications

Equipped With

2019 CORROTEC ZINC NICKEL PROCESS MANUAL PLATING LINE

New 2019

Like New

DETAILED SPECIFICATIONS

 

STATION 1:             MANUAL CART DOCKING STATION

 

§  Painted Steel. floor mounted guide rails to position the manual carts under the hoist rail.

§  Cart Size: 32” DOT x 62” FTB x 77” high

 

STATION 2:              SOAKCLEAN

 

§  Polypropylene Tank Construction

§  Tank Size:  25” DOT x 62” FTB x 64” Deep

§  Tank Volume:  451 gallons (including front weir)

§  Temperature:  1600F

§  Front Overflow (25” DOT x 15” FTB x 30” Deep) with outlet

§  One (1) Recirculation Pump

§  One (1) Hot Water Coil

§  Temperature controller

§  One (1) Level Control for low level pump protection

§  One (1) Ventilation hood

§  One (1) Manual water fill with ball valve

§  One (1) 1-1/2” diameter bottom drain

§  Two (2) Non-electrified saddles

 

STATION 3:              ELECTROCLEAN

 

§  Polypropylene Tank Construction

§  Tank Size:  32” DOT x 62” FTB x 64” Deep

§  Tank Volume:  578 gallons (including front weir)

§  Temperature:  1600F

§  Front Overflow (32” DOT x 15” FTB x 30” Deep)

§  One (1) Recirculation Pump

§  One (1) Hot Water Coil

§  Temperature controller

§  One (1) Level Control for low level pump protection

§  One (1) Ventilation hood

§  One (1) Rectifier

§  Copper bussing for 1,500 amps

§  Two (2) submerged steel-bar grate cathodes

§  One (1) Manual water fill with ball valve

§  One (1) 1-1/2” diameter bottom drain

§  Two (2) Electrified saddles

 


 

 

STATION 4-5:          COUNTERFLOW RINSE

 

§  Polypropylene Tank Construction

§  Tank Size: 52” DOT x 62” FTB x 64” Deep

§  Tank Volume:  ---

§  Temperature:  ---

§  Two (2) Single-leg PVC air spargers with ball valves 

§  One (1) Over/Under Baffle

§  One (1) Overflow Weir with one (1) 1-1/2” drain

§  Two (2) Manual water fills with ball valves

§  One (1) Rotometer (.5-5 GPM)

§  Two (2) 1-1/2” diameter bottom drains

§  Four (4) Non-electrified saddles

 

STATION 6:                        STRIP TANK

 

§  Polypropylene Tank Construction

§  Tank Size:  26” DOT x 62” FTB x 64” Deep

§  Tank Volume:  403 gallons

§  Temperature:  Ambient

§  One (1) Single-leg PVC air sparger with ball valve 

§  One (1) Ventilation hood

§  One (1) Manual water fill with ball valve

§  One (1) 1-1/2” diameter bottom drain

§  Two (2) Non-electrified saddles

 

STATION 7-8:          COUNTERFLOW RINSE

 

§  Polypropylene Tank Construction

§  Tank Size:  52” DOT x 62” FTB x 64” Deep

§  Tank Volume:  ---

§  Temperature:  ---

§  Two (2) Single-leg PVC air spargers with ball valves 

§  One (1) Over/Under Baffle

§  One (1) Overflow Weir with one (1) 1-1/2” drain

§  Two (2) Manual water fills with ball valves

§  One (1) Rotometer (.5-5 GPM)

§  Two (2) 1-1/2” diameter bottom drains

§  Four (4) Non-electrified saddles


 

 

STATION 9:                       ACID PICKLE

 

§  Polypropylene Tank Construction

§  Tank Size:  25” DOT x 62” FTB x 64” Deep

§  Tank Volume:  403 gallons

§  Temperature:  Ambient

§  One (1) Single-leg PVC air sparger with ball valve 

§  One (1) Ventilation hood

§  One (1) Manual water fill with ball valve

§  One (1) 1-1/2” diameter bottom drain

§  Two (2) Non-electrified saddles

 

 

STATION 10:             FUTURE DESMUT

 

§  PVC Drip Shield

§  Size:  39” DOT x 62” FTB

 

STATION 11-12:       FUTURE COUNTERFLOW RINSE

 

§  PVC Drip Shield

§  Size:  59” DOT x 62” FTB x 64” Deep

 

STATION 13:            ZINC-NICKEL PRE-DIP

 

§  Polypropylene Tank Construction

§  Tank Size:  24” DOT x 62” FTB x 64” Deep

§  Tank Volume:  386

§  Temperature:  Ambient

§  One (1) Single-leg PVC air sparger with ball valve

§  One (1) Manual water fill with ball valve

§  One (1) 1-1/2” diameter bottom drain

§  Two (2) Non-electrified saddles


 

 

STATION 14-15:      ZINC-NICKEL PLATE (2-station)

 

§  Polypropylene Tank Construction

§  Tank Size:  94” DOT x 62” FTB x 64” Deep

§  Tank Volume:  1,516 gallons

§  Temperature:  800F

§  Front Overflow (94” DOT x 15” FTB x 23” Deep) with outlet

§  One (1) Recirculation Pump and Filter System with slurry

§  One (1) Titanium Hot Water Coil

§  One (1) Titanium cooling coil

§  Temperature controller

§  One (1) Level Control for low level pump protection

§  One (1) Ventilation hood

§  Two (2) Single-leg CPVC air sparger with ball valve 

§  One (1) Rectifier – Zinc 1,500 amps

§  Copper bussing for 1,500 amps per station - Zinc

§  One (1) Rectifier – Nickel 500 amps

§  Copper bussing for 500 amps per station - Nickel

§  Slab zinc anodes (By Others)

§  Four (4) Titanium anode baskets -nickel anodes by others

§  One (1) Manual water fill with ball valve

§  One (1) 1-1/2” diameter bottom drain

§  Four (4) Electrified saddles

 

STATION 16-17:      COUNTERFLOW RINSE

 

§  Polypropylene Tank Construction

§  Tank Size:  52” DOT x 62” FTB x 64” Deep

§  Tank Volume:  ---

§  Temperature:  ---

§  Two (2) Single-leg PVC air spargers with ball valves 

§  One (1) Over/Under Baffle

§  One (1) Overflow Weir with one (1) 1-1/2” drain

§  Two (2) Manual water fills with ball valves

§  One (1) Rotometer (.5-5 GPM)

§  Two (2) 1-1/2” diameter bottom drains

§  Four (4) Non-electrified saddles

 

STATION 18:      LOAD CART DOCKING STATION

 

v Docking Station (See Section III. Hoist & Structure)

 

 

 

 

STATION 19:            ZINC-NICKEL ACTIVATE

 

§  Polypropylene Tank Construction

§  Tank Size: 24” DOT x 62” FTB x 64” Deep

§  Tank Volume:  386 gallons

§  Temperature:  Ambient

§  One (1) Single-leg PVC air sparger with ball valve 

§  One (1) Manual water fill with ball valve

§  One (1) 1-1/2” diameter bottom drain

§  Two (2) Non-electrified saddles

 

STATION 20:            RINSE

 

§  Polypropylene Tank Construction

§  Tank Size:  24” DOT x 62” FTB x 64” Deep

§  Tank Volume:  ---

§  Temperature:  ---

§  One (1) Single-leg PVC air sparger with ball valve 

§  One (1) Overflow Weir with one (1) 1-1/2” drain

§  One (1) Manual water fill with ball valve

§  One (1) Rotometer (.5-5 GPM)

§  One (1) 1-1/2” diameter bottom drain

§  Two (2) Non-electrified saddles

 

STATION 21:            ZINC-NICKEL CHROMATE #1

 

§  316L Stainless Steel Tank Construction

§  Tank Size:  25” DOT x 62” FTB x 64” Deep

§  Tank Volume:  403 gallons

§  Temperature:  800F

§  One (1) Single-leg PVC air sparger with ball valve 

§  One (1) Stainless Steel Hot Water Coil

§  Temperature controller

§  One (1) Ventilation hood

§  One (1) Single-leg CPVC air sparger with ball valve 

§  One (1) 1-1/2” diameter bottom drain

§  One (1) Manual water fill with ball valve

§  Two (2) Non-electrified saddles

 

 

 

STATION 22-23:      COUNTERFLOW RINSE

 

§  Polypropylene Tank Construction

§  Tank Size:  52” DOT x 62” FTB x 64” Deep

§  Tank Volume:  ---

§  Temperature:  ---

§  Two (2) Single-leg PVC air spargers with ball valves 

§  One (1) Over/Under Baffle

§  One (1) Overflow Weir with one (1) 1-1/2” drain

§  Two (2) Manual water fills with ball valves

§  One (1) Rotometer (.5-5 GPM)

§  Two (2) 1-1/2” diameter bottom drains

 

§  Four (4) Non-electrified saddles

 

STATION 24:            ZINC-NICKEL CHROMATE #2

 

§  316L Stainless Steel Tank Construction

§  Tank Size:  25” DOT x 62” FTB x 64” Deep

§  Tank Volume:  403 gallons

§  Temperature:  800F

§  One (1) Single-leg PVC air sparger with ball valve 

§  One (1) Stainless Steel Hot Water Coil

§  Temperature controller

§  One (1) Ventilation hood

§  One (1) Single-leg CPVC air sparger with ball valve 

§  One (1) 1-1/2” diameter bottom drain

§  One (1) Manual water fill with ball valve

§  Two (2) Non-electrified saddles

 

STATION 25-26:      COUNTERFLOW RINSE

 

§  Polypropylene Tank Construction

§  Tank Size:  52” DOT x 62” FTB x 64” Deep

§  Tank Volume:  ---

§  Temperature:  ---

§  Two (2) Single-leg PVC air spargers with ball valves 

§  One (1) Over/Under Baffle

§  One (1) Overflow Weir with one (1) 1-1/2” drain

§  Two (2) Manual water fills with ball valves

§  One (1) Rotometer (.5-5 GPM)

§  Two (2) 1-1/2” diameter bottom drains

§  Four (4) Non-electrified saddles

 

 

 

 

STATION 27:            ZINC-NICKEL CHROMATE #3

 

§  316L Stainless Steel Tank Construction

§  Tank Size:  25” DOT x 62” FTB x 64” Deep

§  Tank Volume:  403 gallons

§  Temperature:  800F

§  One (1) Single-leg PVC air sparger with ball valve 

§  One (1) Stainless Steel Hot Water Coil

§  Temperature controller

§  One (1) Ventilation hood

§  One (1) Single-leg CPVC air sparger with ball valve 

§  One (1) 1-1/2” diameter bottom drain

§  One (1) Manual water fill with ball valve

§  Two (2) Non-electrified saddles

 

STATION 28-29:      COUNTERFLOW RINSE

 

§  Polypropylene Tank Construction

§  Tank Size:  52” DOT x 62” FTB x 64” Deep

§  Tank Volume:  ---

§  Temperature:  ---

§  Two (2) Single-leg PVC air spargers with ball valves 

§  One (1) Over/Under Baffle

§  One (1) Overflow Weir with one (1) 1-1/2” drain

§  Two (2) Manual water fills with ball valves

§  One (1) Rotometer (.5-5 GPM)

§  Two (2) 1-1/2” diameter bottom drains

§  Four (4) Non-electrified saddles

 

STATION 30:            SEAL

 

§  316L Stainless Steel Tank Construction

§  Tank Size:  25” DOT x 62” FTB x 64” Deep

§  Tank Volume:  403 gallons

§  Temperature:  Ambient

§  One (1) 1-1/2” diameter bottom drain

§  One (1) Manual water fill with ball valve

 

§  Two (2) Non-electrified saddles

STATION 32:      LOAD CART DOCKING STATION

 

v Docking Station (See Section III. Hoist & Structure)

 

STATION 33-A:       ZINC PHOSPHATE

 

§  316 Stainless Steel Tank Construction

§  Tank Size:  28” DOT x 62” FTB x 64” Deep

§  Tank Volume:  451 gallons

§  Temperature:  1800F

§  One (1) Hot Water Coil

§  Temperature controller

§  One (1) Ventilation hood

§  One (1) Manual water fill with ball valve

§  One (1) 1-1/2” diameter bottom drain

§  Two (2) Non-electrified saddles

 

STATION 34-35:      COUNTERFLOW RINSE

 

§  Polypropylene Tank Construction

§  Tank Size:  52” DOT x 62” FTB x 64” Deep

§  Tank Volume:  ---

§  Temperature:  ---

§  Two (2) Single-leg PVC air spargers with ball valves 

§  One (1) Over/Under Baffle

§  One (1) Overflow Weir with one (1) 1-1/2” drain

§  Two (2) Manual water fills with ball valves

§  One (1) Rotometer (.5-5 GPM)

§  Two (2) 1-1/2” diameter bottom drains

§  Four (4) Non-electrified saddles

 

STATION 36:            OIL

 

§  316L Stainless Steel Tank Construction

§  Tank Size:  25” DOT x 62” FTB x 64” Deep

§  Tank Volume:  386 gallons

§  Temperature:  Ambient

§  One (1) 1-1/2” diameter bottom drain

§  One (1) Manual water fill with ball valve

§  Two (2) Non-electrified saddles

 

STATION 37:            OIL DRIP STAND with PAN

 

§  Painted Steel Stand with locating saddles.

§  Size:  22” DOT x 62” FTB x64” height

§  ½” polypropylene pan 22” x 83” x 12” deep

§  Submersible pump to return oil to oil tank (Operator Controlled)

 

SECTION V.             AUXILIARY EQUIPMENT

 

1.     AUXILARY EQUIPMENT MOTOR CONTROL CABINET

 

§  Control cabinet(s) with fused disconnect, fuses, and control transformer (as required).

§  Process controls will be localized where possible

§  IEC motor starters with IEC rated disconnects for local control of equipment. Equipment will be distributed based on locations determined during the design phase of the project.

                  (Panel-1 480V 3PH 100 AMP)

o   One (1) air agitation blower

o   One (1) push air fan

o   One (1) exhaust blower

o   One (1) scrubber pump

 

     (Panel-2 480V 3PH 30 AMP)

o   One (1) cooling coil

o   Wiring of electric components for heating:

o   Two (2) circulation pumps

o   One (1) pump and filter system

 

           

2

Soak Clean

27

Zinc-Nickel Chromate #2

3

Electroclean

30

Zinc-Nickel Chromate #3

14-15

Zinc-Nickel Plate

33

Zinc Phosphate

24

Zinc-Nickel Chromate #1

33-B

Future Zinc Phosphate

 

 

§  All pump systems designed for possible interface to external low-level pump protection.

 

1.     AIR AGITATION BLOWER

 

§  One (1) Regenerative Blower rated at 333 CFM @ 72” including inlet filter silencer, pressure relief valve and pressure gauge.

 

 

 

 

 

2.     RECTIFIERS

 

A.        Electroclean

 

DC Output:

 

One (1) - 1,500 Amperes; 12 Volts

Electrics:

 

 

Volts:

 

480

Phase:

 

3

Hertz:

 

50-60Hz = GND

Cooling:

 

Air-Cooled

Ripple:

 

<3% full range

Setting:

 

0-100% current and voltage

Control:

 

Constant current and voltage control

Control Accuracy:

 

<1%

Degree of Protection:

 

NEMA 2

 

B.        Zinc-Nickel Plate - zinc

 

DC Output:

 

One (1) - 1,500 Amperes; 12 Volts

Electrics:

 

 

Volts:

 

480

Phase:

 

3

Hertz:

 

50-60Hz = GND

Cooling:

 

Air-Cooled

Ripple:

 

<3% full range

Setting:

 

1-100%

Control:

 

Constant current and voltage control

Control Accuracy:

 

<1%

Degree of Protection:

 

NEMA 12

 

C.        Zinc-Nickel Plate - nickel

 

DC Output:

 

One (1) - 500 Amperes; 12 Volts

Electrics:

 

 

Volts:

 

480

Phase:

 

3

Hertz:

 

50-60Hz = GND

Cooling:

 

Air-Cooled

Ripple:

 

<3% full range

Setting:

 

1-100%

Control:

 

Constant current and voltage control

Control Accuracy:

 

<1%

Degree of Protection:

 

NEMA 12

 

 

 

 

4.  RECIRULATION PUMPS

 

·       Soak Cleaner

o   Quantity: One (1) Required

o   1 1/2 HP SS pumps 55 GPM @ 40’ TDH

o   EPDM Seals

 

·       Electroclean

o   Quantity: One (1) Required

o   1 1/2 HP SS pumps 55 GPM @ 40’ TDH

o   EPDM Seals

 

 

5.  FILTER – ZINC-NICKEL

 

·       One (1) Filter chamber:

o   Type:                                       Horizontal

o   Flow Rate:                              4,500 GPH Maximum

o   Filtration Area:                       22 sq. ft.

o   Filter Plate Size:                     Stress relieved Polypropylene

o   Chamber Size:                        24” x 20”

o   Features:                                 Rubber Lined

o   All CPVC piping

 

6. (2) LIFT STATIONS – WASTE RINSE WATER/SCRUBBER WASTE

 

§  One (1) Air-Diaphragm Pump

§  100 Gallon collection tank

§  One (1) Level control

§  One (1) Solenoid valve

 

7.  OPERATOR WALKWAY

 

§  One (1) 48” wide x 108’ long fiberglass walkway supported by steel structure to elevate working height to 42” from top of walkway to top of tanks complete with handrail and stairs as needed. (3) 48” wide 5 step stairs.

 

8.  SAFETY EQUIPMENT

 

·       One (1) combination eyewash/safety shower station on the center catwalk section.

 

9.  FLIGHT BARS (Six (6) Required)

 

·       Flight Bar Description

                       o 1”x 4” copper;

o pick-up points insulated from the copper work bar;

 

o designed to work in conjunction with the locating and electrified saddles;


 

 

10.  REMOVABLE ANODES

 

·       Quantity: Four (4)

·       1” x 4” copper with mild steel pick-up points;

·       pick-up points insulated from the copper work bar;

·       pick up points to match the hoist assembly;

 

11.  SADDLES

 

a.  Non-Electrified Saddles

·       Quantity: As required

·       Material of Construction:  Polypropylene

 

b.  Electrified Saddles

·       Quantity: as required

·       Material of Construction:  Bronze

 

12.  TITANIUM ANODE BASKETS

 

§  Four (4) Anode Baskets

§  Micro Mesh

§  2-1/2” x 6” x 54” long with straps

§  Each basket rated for 50 Amps per basket.

 

 

 

 

13. BATTERY POWERED 10 x 36 PLATING BARREL

 

- ¾”tk PP/LL construction

- ¼” dia. perforations with fully populated panels & doors

- vertically striated

- double snap lock I/O doors

- 1” f protected pp geartrain

- vapor barrier enclosure includes;

o 24Vdc battery driven motor

o Variable speed constant current control motor

o 4.0 amp/hr battery and holder

o Battery capacity display, fuse holder and fuse

- 1x4x68”lg through motor cover copper bar

- 2" lg "V" shaped brass locating horns at each end

- 2 hoist lifting points on each side

- idler gear assembly

- spare battery, charging station & fuses

 

 

14.  CHILLER

One (1) AS-10 Iceman portable chiller, 230 or 460 Volts, 3 Phase, 60 Hertz, complete with:

§  Air-cooled condensing

§  Up to 10 Tons (117,900 BTU/Hr. at 50oF fluid temp) of chilling capacity, using 407C Green Friendly Refrigerant

§  Hermetically sealed scroll compressor

§  Efficient brazed plate evaporator

§  Highly accurate hot gas bypass circuitry, which allows for efficient operation with heat loads as low as 25% of rated capacities eliminating short cycling of compressor

§  Low/high refrigerant gauges

§  Pumping capacity up to 35 GPM and up to 37 PSI. Minimum required flow rate of 24 GPM.

§  1-1/2 Hp pump motor

§  Non-ferrous components on the process fluid and the refrigerant sides

§  Pilot lights: compressor, supply pump, low and high refrigeration pressure, and no fluid flow condition

§  Fluid level visible from outside of cabinet

§  Flow switch to guard against no flow/freeze up condition, due to process fluid restrictions

§  Main power door disconnect

§  Non-proprietary microprocessor based PID controller with LCD indication of set point and Process fluid temperature

§  Compact, powder coated cabinet, mounted on casters for ease of movement and limited floor space requirements

§  System is capable of fluid temperatures of 20°F to 65° F. Factory set for 50oF fluid temperature.

§  If operating below 50oF, consult factory.

§  Designed to meet SPI Guideline for circulating liquid temperature control systems and NFPA 79electrical safety standard for industrial machinery including branch fusing (motor, compressor, and transformer)

§  cULus 508A labeled electrical subpanel

 

 

 

 

15.  HOT WATER BOILER

 

One (1) Boiler, RBI LCD series water heater:

 

1,200,000btu input, 82% efficiency, Low NOx, 2-stage firing, copper heat exchanger, cast iron headers, 75# relief valve, indoor installation, potter flow switch, stainless steel jacket

 

One (1) Pump TACO 1935 cast iron body with SS impeller, 3/4 HP TEFC Motor, 1750 RPM, 2"

FLANGE, 115V/208-230/60/1, 11 Amps, 5.25" IMPELLER TRIM

 

One (1) Controller, Honeywell Model T775B2032 Standard Electronic Temperature Controller

-2 SPDT Output, 1 Floating Output, 2 Input Sensors, 1 Sensor Included

 

One (1) Well, Copper, 0.75" w/ 3.0" insertion for 3/8" bulb. (use with T775's)

 

One (1) Niles ASME jacketed & insulated storage tank, Glass lined, 200 Actual gallons, 32" Dia., 77" Ht., 150 psi, 5-yr warranty

 

One (1) Valve, AMOT 2.5" Flanged Cast Iron Thermostatic Mixing Valve, 140° set with weep hole.

 

 

 

SECTION VI.            VENTILATION SYSTEM

 

PVC PUSH PULL VENTILATION SYSTEM

 

2

Soak Clean

13.4

125

1,671

3

Electroclean

17.1

125

2,139

6

Strip Tank

10.8

125

1,345

9

Acid Pickle

10.8

125

1,345

10

Future Desmut

17.1

125

2,139

14-15

Zinc-Nickel Plate

44.9

125

5,615

21

Zinc-Nickel Chromate #1

10.8

125

1,345

24

Zinc-Nickel Chromate #2

10.8

125

1,345

27

Zinc-Nickel Chromate #3

10.8

125

1,345

32

Zinc Phosphate

12.1

125

1,507

32-B

Future Zinc Phosphate

12.1

125

1507

 

                                                                                                TOTAL CFM            21,305

 

EXHAUST SYSTEM EQUIPMENT:

 

1.     Ten (10) PVC Back up draft exhaust hoods

2.     One (1) Lot PVC duct and fittings

3.     One (1) PVC Fan sized for a total of 21,305 CFM

4.     One (1) Lot PVC outlet transition, exhaust stack, curb cap, and stack cap

 

 

PUSH AIR SYSTEM:

 

1.     One (1) NYB Metal Push Air Blower rated for 326 cfm @ 20-25” H20

2.     One (1) Lot PVC push air pipe and fittings with fiberglass and stainless-steel mounting hardware as required.

 

NOTE: 1) Customer to provide elevated scrubber/fan support structure.

 

2) NO elevated platform is provided for fan/scrubber by Corrotec.

 

3) Customer to provide and install three (3) anchor points for guy wires to support exhaust stack

 

            4) Customer to provide and install roof curb for exhaust stack penetration through roof

 

5) Exhaust rates are designed to remove fumes from the tank surface only.

 

6)     AIR MAKE-UP: Not included in this quotation.

 

7)     It is the customer’s responsibility to determine and provide all air discharge limits and specifications.  Please confirm current EPA/OSHA ventilation regulations as related to the need for either a fume scrubber or mist eliminator in order to meet the existing discharge limits or common housekeeping practices.

 

 

SECTION VI.            VENTILATION SYSTEM

MAPCO FUME SCRUBBER MW-100-20-3-SC horizontal cross flow @ 21,305 CFM, 2.25" SP.

 

INTERNALS - 3 feet of ProPak 3.5 corrosion resistant polypropylene packing, Mapco chevron mist eliminator, 4" of removable MW-5, high efficiency polypropylene mesh pad mist eliminator, 3/8" thick removable flanged spray headers, Delevan, hollow cone spray nozzles.

 

MATERIALS - type II and type I, grade I high and normal impact gray 3/8" thick PVC construction, clear PVC inspection ports, 3/8" thick bolt on pack clean out and fill doors, 3/4" thick inlet and outlet flanges, enamel coated steel channel base with lifting lugs, stainless steel hardware and 100% silicone caulking.

 

SELF CONTAINED RECIRCULATION SYSTEM - to recirculate 137 GPM with 2 GPM freshwater make-up, sump box, overflow, drain, 5 HP 230/460/3/60 CPVC vertical pump, gate
valve, strainer and blow-down flowmeter.

 

ACCESSORIES - liquid level control, secondary mechanical float valve, fresh water solenoid valve, magnehelic gauge to indicate pressure drop across the wet scrubber.

 

TRANSITIONS - inlet and outlet transitions constructed of 3/16" and or 1/4" type II, grade I, white corrosion-resistant PVC with 2" X 3/4" thick mating flange and external reinforcing, silicone caulking, stainless steel bolts, lock washers, flat washers and nuts.

 

 

pH CONTROL SYSTEM - to include pre-amp, holder, electrode, chemical feed pump and 110/1/60 pH controller mounted inside a NEMA 4x enclosure.

 



 

 

 

Attachments

There are no files attached to this listing currently. If you Have any further questions regarding this listing, please contact us for more information.

Blumberg Machinery is proud to offer a slew of services from appraisals, financing, auction services, and more.

View All Services